PowerWalker AVR 2000/SIV
•2000VA / 1600W Automatic Voltage Regulator
•Schuko Input, 1x Schuko Outlet
•N/A
•Selectable input voltage range
•Time Delay function eliminates transients that can affect connected equipment
•Microprocessor Control guarantees high reliability
•Schuko Input, 1x Schuko Outlet
•N/A
•Selectable input voltage range
•Time Delay function eliminates transients that can affect connected equipment
•Microprocessor Control guarantees high reliability
PowerWalker AVR SIV Series are automatic voltage regulators with selectable
input voltage 150-270VAC or wide 110-280VAC. It provides output voltage
within allowed limit of +/-10% (207-253VAC) through boost and buck
stabilizers. The built-in thermal sensor provides over-temperature protection
and recover, while abnormal situation is eliminated.
The device works in following modes depending on input voltage:
Input 252-270/280V – buck mode -10% in regards to input voltage
Input 207-252VAC – normal operation
Input 173-211VAC – first boost +20%
Input 110/150-178VAC – second boost +40%
Input Additionally you can turn on protection delay function which will increase
protection reaction time from 10s to 3 minutes for less sensitive device
input voltage 150-270VAC or wide 110-280VAC. It provides output voltage
within allowed limit of +/-10% (207-253VAC) through boost and buck
stabilizers. The built-in thermal sensor provides over-temperature protection
and recover, while abnormal situation is eliminated.
The device works in following modes depending on input voltage:
Input 252-270/280V – buck mode -10% in regards to input voltage
Input 207-252VAC – normal operation
Input 173-211VAC – first boost +20%
Input 110/150-178VAC – second boost +40%
Input Additionally you can turn on protection delay function which will increase
protection reaction time from 10s to 3 minutes for less sensitive device
Technical Specification:
Power capacity: 2000VA / 1600W
Output Power Factor: 0.80
Input
Input Voltage Range: 110-280 VAC or 150-270 VAC
Frequency Range: 50Hz or 60Hz
Output
Voltage Regulation (Bat. Mod.): ±10%
Protection: Over-voltage, Under-voltage, Over-heat, Over-current, Surge, Spike Suppression
LED Indicators: Normal Mode, AVR Mode, Delay Time, Fault
Efficiency:
LINE mode full Load
95%
Output Power Factor: 0.80
Input
Input Voltage Range: 110-280 VAC or 150-270 VAC
Frequency Range: 50Hz or 60Hz
Output
Voltage Regulation (Bat. Mod.): ±10%
Protection: Over-voltage, Under-voltage, Over-heat, Over-current, Surge, Spike Suppression
LED Indicators: Normal Mode, AVR Mode, Delay Time, Fault
Efficiency:
LINE mode full Load
95%
For more information:
http://www.powerwalker.com/?page=product&item=10120306&lang=en
http://www.powerwalker.com/?page=product&item=10120306&lang=en
Manufacturer | POWERWALKER |
Warranty | 24 months |
Barcode | 4260074976809 |
Nominal input voltage |
230 VAC
|
Capacity |
2000VA / 1600 W
|
Output Voltage |
± 10 %
|
Input Connections |
1x Schuko
|
Outlets |
2 Schuko
|
Protection |
Short-Circuit Protection
Overload Protection
Over-temperature protection
|
Dimension (mm) |
233,6 x 134 x 181
|
Weight | 6.550 kg |